Medical Researches  

Go Back   Medical Researches > LOST RESEARCHES IN SOME COUNTRIES > Germany
FAQ Members List Calendar Search Today's Posts Mark Forums Read

Reply
 
LinkBack Thread Tools Display Modes
  #1 (permalink)  
Old 01-24-2008, 04:53 PM
lecturer lecturer is offline
Senior Member
 
Join Date: Jan 2008
Posts: 132
Default Scleral buckling surgery and pneumatic retinopexy : Techniques, indications and resul

ads
Scleral buckling surgery and pneumatic retinopexy : Techniques, indications and results

For many decades, conventional buckling surgery has been the gold standard for treating rhegmatogenous retinal detachment. The surgical technique has not changed markedly during this period; the three main buckling techniques currently used are the radial sponge, segmental sponge, and encircling band. With one of these options, an anatomic success rate of over 90% can be achieved in "simple" forms of retinal detachment. In pseudophakic eyes, however, the primary reattachment rate after buckling procedures is lower. Pneumatic retinopexy, because of its lower success rate, has not found general acceptance in Europe and is used only in selected cases. Concerning the results of the SPR study, many vitreoretinal surgeons were surprised that in the subgroup of phakic eyes, scleral buckling surgery achieved a comparable reattachment rate and better functional results even in this group of patients with complex hole configuration. This gives physicians reason to critically question the current trend of primary vitrectomy even in eyes with uncomplicated preoperative pathology and to reassess scleral buckling surgery. The longer learning curve to perform buckling surgery should be accepted. Because successful repair depends on careful preoperative examination, thorough training in binocular ophthalmoscopy skills with scleral depression should remain an essential part of the surgeon's education.


Ophthalmologe. 2007 Dec 20

[Article in German]

Hoerauf H, Heimann H, Hansen L, Laqua H.

Universit?ts-Augenklinik, Robert-Koch-Stra?e 40, 37075, G?ttingen, Deutschland, hanshoerauf@yahoo.com.
ads
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Böcek ilaçlama , yurt ,
All times are GMT. The time now is 10:53 PM.


Powered by vBulletin® Version 3.6.8
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
SEO by 3.0.0

sitemap
burs , burs anadolu jet kpss , , anadolu jet ,
34 35 36 37 39 40 44 46 47 48 49 50 51 52 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68