Medical Researches  

Go Back   Medical Researches > LOST RESEARCHES IN SOME COUNTRIES > Turkey
FAQ Members List Calendar Search Today's Posts Mark Forums Read

Turkey some researches in Turkey (istanbul ,Marmara,Hacettepe,Ankara uni.)

Reply
 
LinkBack Thread Tools Display Modes
  #1 (permalink)  
Old 01-23-2008, 08:03 PM
lecturer lecturer is offline
Senior Member
 
Join Date: Jan 2008
Posts: 132
Default Comparison of the effectiveness of the traditional acupuncture point, ST. 36 and Omur

ads
Comparison of the effectiveness of the traditional acupuncture point, ST. 36 and Omura's ST.36 Point (True ST. 36) needling on the isokinetic knee extension & flexion strength of young soccer players.


The purpose of this study was to compare the effects of the Traditional acupuncture point ST.36 and 'Omura's ST.36 Point' ("True ST.36") needling on the isokinetic knee extension & flexion strength of young soccer players. The Bi-Digital O-Ring Test (B.D.O.R.T.) of Yoshiaki Omura, M.D.,Sc.D. was used to determine the "True ST.36". Young soccer players (N = 24) between 16-18 years of age (Mean = 16.92 +/- 0.65) were involved in the study. The extension & flexion strengths of dominant legs were measured with Cybex 350 Extremity System isokinetically. The testing velocity was 60 degrees/sec. The peak torque value in Newton meters (Nm) was evaluated. Subjects were tested 3 times. Extension & Flexion 1 (EXT1, FLEX1) without acupuncture application, EXT2 & FLEX2 after application on the traditional acupuncture point, ST.36 and EXT3 & FLEX3 after application onto the 'Omura's New Foot-point' ("True ST.36"). Before each test, subjects warmed up for 10 minutes by cycling on an isokinetic ergometer at 50 RPM, 75 Watts load followed by stretching exercises of lower extremity. Mean EXT1, EXT2, EXT3 values were 196.92 +/- 28.70: 210.00 +/- 23.00; 224.42 +/- 21.70 respectively, where FLEX1, FLEX2, FLEX3 were 140.88 +/- 22.45; 151.13 +/- 21.27; 161.00 +/- 22.23. Comparisons of EXT1-EXT2, EXT1-EXT3, EXT2-EXT3, FLEX1-FLEX2, FLEX1-FLEX3, FLEX2-FLEX3 strength values showed all very high significance (P < 0.001) in favor of 1) Needling on relevant points and 2) Omura's ST.36 Point ("True ST.36"). We conclude that B.D.O.R.T. can help to determine new (True) Acupuncture points and, both points were effective for increasing the isokinetic knee extension & flexion strength of young soccer players very significantly where as Omura's ST.36 Point ("True ST.36") was more effective than Traditional Acupuncture point, ST.36.

Acupunct Electrother Res. 2007;32(1-2):71-9.
Ozerkan KN, Bayraktar B, Sahinkaya T, Goksu OC, Yucesir I, Yildiz S.

Istanbul University, School of Physical Education and Sport, Physical Education Teaching Department. kozerkan@gmail.com
ads
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Böcek ilaçlama , yurt ,
All times are GMT. The time now is 07:02 AM.


Powered by vBulletin® Version 3.6.8
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
SEO by 3.0.0

sitemap
burs , burs anadolu jet kpss , , anadolu jet ,
34 35 36 37 39 40 44 46 47 48 49 50 51 52 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68